14.5.1 Performing Measurements
Useful commands for performing measurements described elsewhere
INITiate<n>:ESPectrum on page 919
INITiate<n>:SPURious on page 953
Remote commands exclusive for performing measurements:
ABORt.......................................................................................................................... 834
INITiate<n>:CONMeas................................................................................................... 835
INITiate<n>:CONTinuous................................................................................................835
INITiate<n>[:IMMediate]..................................................................................................836
[SENSe:]SWEep:COUNt:CURRent?................................................................................836
ABORt
This command aborts the measurement in the current channel and resets the trigger
system.
To prevent overlapping execution of the subsequent command before the measure-
ment has been aborted successfully, use the *OPC? or *WAI command after ABOR and
before the next command.
For details see Chapter 13.1.6.1, "Preventing Overlapping Execution", on page 750.
Note on blocked remote control programs:
If a sequential command cannot be completed, for example because a triggered sweep
never receives a trigger, the remote control program will never finish and the remote
channel to the R&S FSW is blocked for further commands. In this case, you must inter-
rupt processing on the remote channel first in order to abort the measurement.
To do so, send a "Device Clear" command from the control instrument to the R&S FSW
on a parallel channel to clear all currently active remote channels. Depending on the
used interface and protocol, send the following commands:
Visa: viClear()
GPIB: ibclr()
RSIB: RSDLLibclr()
Now you can send the ABORt command on the remote channel performing the mea-
surement.
Example:
ABOR;:INIT:IMM
Aborts the current measurement and immediately starts a new
one.
Example:
ABOR;*WAI
INIT:IMM
Aborts the current measurement and starts a new one once
abortion has been completed.
Usage: Event