Rockwell Automation Publication 2198-UM002L-EN-P - October 2021 181
Chapter 6 Configure and Start the Kinetix 5700 Drive System
Table 108 - Navigating the Regenerative Bus Supply Menu
Menu/Sub Menu
Selections
Attributes Description Example Values
Module Info
Catalog number 2198-RPxxx
Firmware revision
FW REV: 10.1.10500409
Hardware revision
HW REV: 2.1
Serial number SERIAL#: xxxxxxxxxxx
Diagnostics>
Converter
Diagnostics
Converter diagnostics
CONV UTIL: 0.7%
CONV TEMP: 31.7C
SHUNT UTIL: 0.0%
DC BUS: 0.0V
IBUS: 0.0A
CONV UTIL: 0.0%
CONV TEMP: 22.6C
PWR OUT: 0.0kW
IGND:0.0A RMS
AC FREQ: 0.1Hz
IL1: 0.0A RMS
IL2: 0.0A RMS
IL3: 0.0A RMS
VL1-2: 0.0V RMS
VL2-3: 0.0V RMS
VL3-1: 0.0V RMS
VL1-N: 0.0V RMS
VL2-N: 0.0V RMS
VL3-N: 0.0V RMS
VBUS REF: 690V
SYNC STS: 0
ACT PWR: 0.0kW
PF: 0.0
VAC UNBAL: 0.0%
IAC UNBAL: 0.0%
PHASE SEQ: 0.0
Digital Inputs
IN1: OFF
IN2: OFF
IN3: OFF
IN4: OFF
Digital Outputs
CONT ENABLE: 0
PWR SUP OK: 0
Fault Log
Fault text
Fault code as listed in the Kinetix 5700 Fault Codes.xlsx file.
(1)
FLT S23 – AC PHASE LOSS
Fault details
The problem as reported in the Kinetix 5700 Fault Codes.xlsx file.
(1)
One AC phase has been lost on the AC line to the
converter.
Fault help
The Possible Solution as reported in the Kinetix 5700 Fault Codes.xlsx file.
(1)
Check AC input voltage on all phases.
(1) For Kinetix 5700 fault code descriptions and possible solutions, see Kinetix 5700 Servo Drive Fault Codes, publication 2198-RD003.