Rockwell Automation Publication 2198-UM002L-EN-P - October 2021 205
Chapter 6 Configure and Start the Kinetix 5700 Drive System
The New Module dialog box appears.
4. Configure the new drive.
a. Type the drive Name.
b. Select an Ethernet Address option.
In this example, the Private Network address is selected.
c. Enter the address of your 2198-xxxx-ERSx inverter.
In this example, the last octet of the address is 6.
d. Click Advanced if using network address translation with safety
connection to add drive module configured IP address.
The fields to configure in the Module Definition dialog box are dependent on
your drive, Logix Designer version, and drive firmware revision. Use the
following table to navigate to the series of steps intended for your drive
system.
Table 116 - How to Navigate Module Definition
For Drive Cat. No. Logix Designer Version Drive Firmware Revision Go to:
2198-xxxx-ERS3 (series A) 30 or earlier 7 or earlier Configure Module Definition for 2198-xxxx-ERS3 (series A) Drives
on page 206
2198-xxxx-ERS3 (series B)
2198-xxxx-ERS4
31 or later 9 or later
Configure Module Definition for 2198-xxxx-ERS4 and 2198-xxxx-ERS3 (series B)
Drives on page 207