Regularly check the lubricating pipe system. Check daily whether the lubricating sys-
tem works without faults. One option is to check the two or three main distributors. An
indicator pin is installed there for checking functioning. This indicator pin moves slowly
when the grease flows through the main distributor. This shows whether the pump ele-
ment of this lubricating circuit is operating.
1
Main distributor support
1
Main distributor chassis
1
Main distributor at recleaner
(1) Indicator pin