Maintenance and Service
Diesel engine
318 / 476
Proceed on the cleaning of the cooling system as follows:
Switch off the engine and secure the machine against inadvertent starting (pull off
the ignition key and take it with you).
Fold down the rear platform wall (4).
4
Release the rubber closures (6) on the intake grid.
Swing up the intake grid (5).
Clean the intake grid from the collected dirt with the brush and, if necessary, with
the water stream from the water hose.
5
6
(5) Intake grid
(6) Front rubber closure
CAUTION
Danger to eyes and skin injury due to foreign bodies blowing out.
The powerful air flow of the fan may cause injuries to eyes and skin by particles of dirt
blown by the air stream.
Persons must not be on the boarding platform during automatic reversing.
Fold up the rear platform wall, close the cabin door, start the engine and wait for
the automatic reversing program for the fan.
Switch off the diesel engine and secure the machine against inadvertent starting
(pull off the ignition key and take it with you).
Pull the locking lever for the ventilator cowl (7) and fold it up.

Table of Contents