128 TimeProvider 2300/2700 User’s Guide 098-00564-000 Revision A3 – July, 2013
Chapter 3
TimeProvider 2300/2700 CLI Command Set
------------------------------
|Index |address |
|-------|--------------------|
|1 |192.168.9.41 |
|.......|....................|
|2 |0.0.0.0 |
------------------------------
Example 10:
To show the status for PTP clients on ETH1 port:
TP2700>show ptp client status eth1
Response 10:
ETH1 PTP CLIENT STATUS:
Client Status : OK
Minimal Round Trip Delay(us) : 0.74
METRIC : FORWARD REVERSE
Flow Weight (%) : 47.79 52.21
Transient free out of 900s : 900 900
Transient free out of 3600s : 3600 3600
Percentile Clustering (%) : 100.0 100.0
Operational Min TDEV (ns) : 98.0 98.1
Operational MAFE (ppb) : 0.00 0.00
Min Cluster Width (ns) : 15000.0 7500.0
Mode width (ns) : 30000.0 15000.0
Packet Rate (pkts/s) : 64 64
Currently Used Master:
IP Address : 192.168.9.41
Clock ID : 00:b0:ae:ff:fe:03:46:69
Port Number : 2
Clock Class : 6
Clock Accuracy : within 100 ns
Time Scale : PTP
Time Source : GPS
Time Traceable : true
Frequency Traceable : true
Steps Removed : 1