098-00564-000 Revision A3 – July, 2013 TimeProvider 2300/2700 User’s Guide 127
Chapter 3
TimeProvider 2300/2700 CLI Command Set
Example 8:
To show the status of PTP master on ETH2 port:
TP2700>show ptp master status eth2
Response 8:
ETH2 PTP MASTER STATUS :
Port enabled : yes
Clock Id : 00:b0:ae:ff:fe:03:46:69
Port Number : 2
Profile : telecom-2008
Port state : master
Clock class : 6
Clock accuracy : within 100 ns
Timescale : ptp
Maximum allowed clients : 64
Number of attached clients : 1
Client load : 1%
Example 9:
To show the Telecom-2008 configuration info for PTP client on ETH1 port:
TP2700>show ptp client config eth1 telecom-2008
Response 9:
ETH1 PTP CLIENT CONFIGURATION WITH PROFILE TELECOM 2008:
PTP State : enable
PTP TTL : 64
PTP DSCP : 0
PTP Unicast Negotiation : enable
PTP Unicast Lease Duration : 300
PTP Sync Interval : -6
PTP Announce Interval : 1
PTP Delay Interval : -6
PTP Clock Id : 00:b0:ae:ff:fe:03:46:05
PTP Domain : 0
PTP Announce Receipt Timeout : 3
PTP master-table: