the system has executed end point of current path;
● △d,△u are specified by the same U and different with or without being specified P, Q
commands;
● G71 cannot be executed in MDI, otherwise, the system alarms;
● There are no the same block number in ns~nf when compound cycle commands are
executed repetitively in one program;
● The tool retraction point should be high or low as possible to avoid crashing the
workpiece.
Example:Fig. 3-73(Type I)
Fig. 3-27