TOMATECH AUTOMATION
Tool signal7/pre-graduation proximity switch
(Yantai AK31)
Also as
OV3 input
T08 CN61.11 X1.2
Tool signal8/tool post worktable overheat
check(Yantai AK31)
Also as
OV4 input
Input
signal
TCP CN61.35 X2.6 Tool post locking signal
TL+ CN62.15 Y1.6 Tool post rotation(CW) signal
TL- CN62.16 Y1.7 Tool post rotation(CCW) signal
TZD/TLS CN62.29 Y2.0
Tool post worktabke brake(Yantai AK31)/
tool pot releasing(Liuxin Tool Post)
Output
signal
INDXS/
TCLP
CN62.30 Y2.1
Tool post worktable pregraduation coil (Yantai
AK31)/tool pot lock(Liuxin Tool Post)
� Control parameter
Bit parameter
K 1 1 CHOT CHET TCPS CTCP TSGN CHTB CHTA
CHTA: tool change mode selection bit 0
CHTB: tool change mode selection bit 1(see following table)
TSGN =0 : tool signal HIGH(turn on +24V) is valid
=1 : tool signal LOW(turn off +24V) is valid
CTCP =0 : do not check tool post locking signal
=1 : check tool post locking signal
TCPS =0 : tool post locking signal LOW(turn off +24V) is valid
=1 : tool post locking signal HIGH(turn on +24V) is valid
CHET=0 : do not check tool signal after the tool change is completed
CHTB CHTA Tool post type
0 0 Standard tool change mode B
0 1 Standard tool change mode A
1 0 Yantai AK31
1 1 Unused
326
Ⅲ Connection