TOMATECH AUTOMATION
=1 : check tool signal after the tool change is completed
CHOT=0 : do not check tool post overheat
=1 : check tool post worktable overheat
D T 0 4 TLMAXT
The maximum time limit for tool change
D T 0 7 T1TIME
Tool change time T1: Tool post delay time from CCW stop to CW output (ms)
D T 0 8 TCPCKT
Tool post lock signal detection time (ms)
D T 0 9 TCPTIME
Tool change time T2: tool post CW rotation locking time
0 0 8 4 TMAX
Total tools selection
� Signal connection
1. The T01~T08, TCP signals input are employed with photocoupler, its interior circuit is
shown
in Fig. 2-35:
Fig. 2-35
2. TL+, TL- are tool post CCW/CW output signal, its interior circuit is shown in Fig.2-36:
Fig. 2-36
3. The external circuit of the tool number signal is shown in Fig. 2-37, when the tool
number
signal is low level active, it requires an external pull-up resistor.
+24V
ULN2803
TL+/TLCNC
sCiNdCe侧
Output signal
Machine side
Chapter 2 Definition and Connection of Interface Signal
327
Ⅲ Connection
·
Fig. 2-37
� Function description (defined by standard PLC program)
The control sequence and control logic of the tool change are defined by PLC program.
There
are 4 tool change modes defined as follows by standard PLC program:
1. CHTB (K11.1)=0, CHTA (K11.0)=0: tool change mode B
①During the tool change process, CNC outputs TL+ signal until the tool in-position signal
is
detected, then CNC turns off TL+ signal output and outputs TL- signal after a delay time
specified by data parameter No.082. Then CNC detects TCP signal till it is detected, the
CNC