TOMATECH AUTOMATION
rotary
axis (A-type); 11: set the additional axis to the rotary axis (B-type); 10: set the
additional to be invalid.
1 9 6 MSI CSS MSEN
Bit7 1: The multiple spindle control B type;
0: The multiple spindle control A type.
Bit6 1: In the multiple spindle control, the system separately controls Cs contour of each
spindle;
0: In the multiple spindle control, the system controls the Cs contour of only the 1st
spindle.
Bit4 1: The multiple spindle control function is valid;
0: The multiple spindle control function is invalid;
K 1 5 RCS RSCS
RCS =1: The spindle Cs function is valid;
=0: The spindle Cs function is invalid.
RSCS =1: The spindle contour control is disabled in emergency stop, reset;
=0: The spindle contour control is enabled in emergency stop, reset.
352
Connection
K 1 7 MSEN SALM2
MSEN =1: The multiple spindle control function is valid;
=0: The multiple spindle control function is invalid.
SALM2 =1: The system alarms when the check input signal of the 2nd spindle abnormality
is
LOW;
=0: The system alarms when the check input signal of the 2nd spindle abnormality is
HIGH;
Function description(defined by the standard PLC program
1.1. After the multiple spindle control function setting is valid, the system defaults to the 1st
spindle control after power-on;
1.2. When M03, M04, M05 is executed, the corresponding signal of the 1st spindle outputs,
at
that time, the system sets the 1st spindle control, hereafter, the S command being
executed
will change the 1st spindle speed. In a similar way, M63, M64, M65 is executed, the
corresponding signal of the 2nd spindle outputs, at the time, the corresponding signal of
the
2nd spindle outputs, and is switched into the 2nd spindle control, after that, the executed S
command will change the 2nd spindle speed.
1.3. The spindle switch is invalid in rigid tapping.
1.4. The manual CW, CCW, STOP, SPINDLE OVRRRIDE keys on the panel are valid
only to the
1st spindle. When the current system is controlled by the 2nd spindle, the manual control

Table of Contents