TOMATECH AUTOMATION
① When the tool count is less than 10, the gear and the tool number separately use one
LED to
display.
② When the tool count is more than 10, LED 1 displays 10-digit numbers and the LED 0
displays the single digits.
③ When the gear and the tool number are displayed in time-division, that is, the gear
instead of
the tool number is firstly display, the tool number instead of the gear is displayed after
1.5S, and the
system executes them like the above cycle.
2.9 Commonly Use Sign of Electricity Drawing
TAC-100XT DC24V power supply and the electromagnetic valve with power working
current
separately use DC24V, and the electronic component explanations are as follows:
Name Sign Graph Name Sign Graph
Air breaker QF
Contactor coil
contact and auxiliary
contact
KM
transformer TC
Heat relay and
contact
FR
Rectifier VC
Capacity C
Motor M
Resistant R
Diode VD Hall switch
368
Ⅲ Connection
Electromagnetic
coil
YV
Travel switch SQ
Veneer socket
Pedal switch SA
Relay coil and
contact
KA
Fuse FU
Chapter 3 Parameters