TOMATECH AUTOMATION
program
code in auto running
Data unit
Setting unit IS-B IS-C
Metric input 0.001 mm 0.0001 mm
Inch input 0.0001 inch 0.00001 inch
Data range -99999999999999
0 5 5 PATIM
Data meaning Cycle times of G73, which may also be changed by program code in
auto
running
384
Volume Connection
Data unit times
Data range 19999
0 5 6 GROVE
Data meaning Retraction value of Z axis in G74; retraction value of X axis in G75; a
specified
value in program during automatic running can also change the setting of this
parameter;
Data unit
Setting unit IS-B IS-C
Metric input 0.001 mm 0.0001 mm
Inch input 0.0001 inch 0.00001 inch
Data range 099999
0 5 7 THRPT
Data meaning Repetitions of G76 finish machining, which may also be changed by
program
code in auto running
Data unit times
Data range 199
0 5 8 THANG
Data meaning Tool nose angle of G76 cycle, which may also be changed by program
code in
auto running
Data unit deg
Data range 099
0 5 9 THCLM
Data meaning Min. cut depth of G76 cycle, which may also be changed by program
code in
auto running
Data unit