radius, the X axis value is specified by radius.
0 4 7 PRSn
[Data type] Word axis
[Data meaning] Setting value of absolute coordinate after machine zero return
[Data unit]
Setting unit IS-B IS-C
Metric input 0.001 mm 0.0001 mm
Inch input 0.0001 inch 0.00001 inch
[Data range] -99999999~99999999
Chapter 3 Parameters
383
Volume Ⅲ Connection
0 5 1 MRCCD
[Data meaning] Each feeding for G71, G72 rough turning cycle, which may also be
changed by
program code in auto running.
[Data unit]
Setting unit IS-B IS-C
Metric input 0.001 mm 0.0001 mm
Inch input 0.0001 inch 0.00001 inch
[Data range]
IS-B IS-C
Metric input 1~99999 1~999999
Inch input 1~99999 1~999999
0 5 2 MRCDT
[Data meaning] Each retraction for G71, G72 rough turning cycle, which may also be
changed
by program code in auto running.
[Data unit]
Setting unit IS-B IS-C
Metric input 0.001 mm 0.0001 mm
Inch input 0.0001 inch 0.00001 inch
[Data range] 0~99999
0 5 3 PECSCX
[Data meaning] X retraction amount in G73, which may be also changed by program
code in
auto running.
[Data unit]
Setting unit IS-B IS-C
Metric input 0.001 mm 0.0001 mm
Inch input 0.0001 inch 0.00001 inch
[Data range] -9999999~9999999
0 5 4 PECSCZ
[Data meaning] Z axis rough turning retraction in G73, which may also be changed by

Table of Contents