EasyManua.ls Logo

TOMATECH TAC-100XT - Page 320

TOMATECH TAC-100XT
415 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
TOMATECH AUTOMATION
0 4 0 GRMAX4
Data meaning GRMAX1, GRMAX2, GRMAX3, GRMAX4: Max. speeds of gear 1, 2, 3,
4
respectively when spindle analog voltage output is 10V (the function defined
byTAC-1002T PLC is: if the spindle automatic gearing is active, it uses the
speeds of M41, M42, M43, M44; if the automatic gearing is inactive or CNC is
powered on, the gear is memorized by parameter or the gear 1 is defaulted.)
Data unit r/min
Data range 109999
382
Volume Connection
0 4 1 JOGFL
Data meaning Exponential ac-deceleration start speed and deceleration final speed in
manual feed
Data unit
Setting unit Data unit
Metric machine mm/min
Inch machine 0.1inch/min
Data range 08000
0 4 2 SEQINC
Data meaning Block No. increment for auto block No. insertion
Data range 1100
0 4 3 LOWSP
Data meaning (G96) Spindle min. speed under the constant surface speed control
Data unit r/min
Data range 09999
0 4 4 BRATE0
Data meaning Serial communication baud rate,
Data unit bit/s
Data range 1200,2400,4800,9600,19200,38400 57600 115200
0 4 5 LT1X1
0 4 6 LT1Z1
Data type Word axis
Data meaning LT1X1X,LT1Z1Zpositive max. travelLT1X2X,LT1Z2Z
negative
max. travel
Data unit
Setting unit IS-B IS-C
Metric machine 0.001 mm 0.0001 mm
Inch machine 0.0001 inch 0.00001 inch
Data range -9999999999999999
Note: If the BIT2 of the parameter No.001 is set for diameter, the X axis value is specified by
diameter; if for

Table of Contents