Data type Word axis
Data meaning Rapid traverse rate as axis rapid override is F0
Data unit
Setting unit Data unit
Metric machine mm/min
Inch machine 0.1inch/min
Data range
IS-B IS-C
Metric machine 04000 04000
Inch machine 01500 01500
0 3 3 ZRNFLn
Chapter 3 Parameters
381
Volume Connection
Data type Word axis
Data meaning Low rate as axes return to machine zero
Data unit
Setting unit Data unit
Metric machine mm/min
Inch machine 0.1inch/min
Data range
IS-B IS-C
Metric machine 64000 64000
Inch machine 31500 31500
0 3 4 BKLn
Data type Word axis
Data meaning backlash compensation of each axis
Data unit
Setting unit IS-B IS-C
Metric machine 0.001 mm 0.0001 mm
Inch machine 0.0001 inch 0.00001 inch
Data range
Setting unit IS-B IS-C
Metric machine 02000 020000
Inch machine 02000 020000
Note : X is the diameter value.
0 3 6 SPDLC
Data type Word spindle
Data meaning Voltage offset for 0V analog voltage output of spindle min. speed code
Data unit mV
Data range -10001000
0 3 7 GRMAX1
0 3 8 GRMAX2
0 3 9 GRMAX3