[Data type] Word axis
[Data meaning] Rapid traverse rate as axis rapid override is F0
[Data unit]
Setting unit Data unit
Metric machine mm/min
Inch machine 0.1inch/min
[Data range]
IS-B IS-C
Metric machine 0~4000 0~4000
Inch machine 0~1500 0~1500
0 3 3 ZRNFLn
Chapter 3 Parameters
381
Volume Ⅲ Connection
[Data type] Word axis
[Data meaning] Low rate as axes return to machine zero
[Data unit]
Setting unit Data unit
Metric machine mm/min
Inch machine 0.1inch/min
[Data range]
IS-B IS-C
Metric machine 6~4000 6~4000
Inch machine 3~1500 3~1500
0 3 4 BKLn
[Data type] Word axis
[Data meaning] backlash compensation of each axis
[Data unit]
Setting unit IS-B IS-C
Metric machine 0.001 mm 0.0001 mm
Inch machine 0.0001 inch 0.00001 inch
[Data range]
Setting unit IS-B IS-C
Metric machine 0~2000 0~20000
Inch machine 0~2000 0~20000
Note : X is the diameter value.
0 3 6 SPDLC
[Data type] Word spindle
[Data meaning] Voltage offset for 0V analog voltage output of spindle min. speed code
[Data unit] mV
[Data range] -1000~1000
0 3 7 GRMAX1
0 3 8 GRMAX2
0 3 9 GRMAX3