EasyManuals Logo

TOMATECH TAC-100XT User Manual

TOMATECH TAC-100XT
415 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #324 background imageLoading...
Page #324 background image
TOMATECH AUTOMATION
0 7 3 SPMOTORMAX
Data type Word spindle
Data meaning Max. spindle motor clamping speed, setting value=(max. spindle motor
clamping speed/max. spindle motor speed) ×4095
Data unit r/min
Data range 04095
Setting value =max. clamp speed of spindle/max. speed of spindle motor×4095.
386
Volume Connection
0 7 4 SPMOTORMIN
Data meaning Min. spindle motor clamping speed, setting value=(min. spindle motor
clamping speed/max. spindle motor speed) ×4095
Data unit r/min
Data range 04095
Setting value =min. clamping speed of spindle motor/max. speed of spindle motor×4095
0 7 5 SPSPEEDLIMIT
Data type Word spindle
Data meaning Maximum spindle rev speed(0~6000r/min)[0:unlimited]
Data unit r/min
Data range 06000
0 8 4 TMAX
Data meaning Total tools number selection
Data unit piece
Data range 132
0 9 6 PECMINn
Data type Word axis
Data meaning Minimum pitch error compensation position number
Data range 01023
0 9 7 PECMAXn
Data type Word axis
Data meaning Maximum pitch error compensation position number
Data range 01023
0 9 8 PECORGn
Data type Word axis
Data meaning Pitch error compensation position numbers corresponding to machine
zero
points
Chapter 3 Parameters
387
Volume Connection
Data range 01023
0 9 9 PECINTn
Data type Word axis