EasyManuals Logo

TOMATECH TAC-100XT User Manual

TOMATECH TAC-100XT
415 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #325 background imageLoading...
Page #325 background image
TOMATECH AUTOMATION
Data meaning Pitch error compensation intervals
Data unit
Setting unit IS-B IS-C
Metric machine 0.001 mm 0.0001 mm
Inch machine 0.0001 inch 0.00001 inch
Data range
IS-B IS-C
Metric machine 1000999999 100009999999
Inch machine 400999999 40009999999
1 0 6 THD_SPD_VAR
Data meaning Spindle fluctuation alarm limit in threading (not detect spindle
fluctuation alarm
if set to 0)
Data unit %
Data range 0100
Formula=|current speed previous period speed|×200/(current speedprevious period
speed)
1 0 7 THD_TAIL_SPD
Data meaning Short axis speed in threading run-out (run-out by threading feedrate if
set to 0)
Data unit
Setting unit Data unit
Metric machine mm/min
Inch machine 0.1inch/min
Data range 08000
1 0 9 SPL_REV_SPD
Data meaning Spindle jog speed (r/min)
Data unit r/min
Data range 18000
1 1 0 MGR
Data type Word spindle
Data meaning Gear ratio of encoder to spindle: spindle gear teeth number
Data range 1255
1 1 1 SGR
Data type Word axis
388
Volume Connection
Data meaning Gear ratio of encoder to spindle: encoder gear teeth number
Data range 1255
1 1 3 REF_SPDn
Data type Word axis
Data meaning Axes rapid traverse rates in machine zero return
Data unit