TOMATECH AUTOMATION
Setting unit Data unit
Metric machine mm/min
Inch machine 0.1inch/min
Data range 1099999999
1 1 4 REF_OFFSETn
Data type Word axis
Data meaning Offset of each axis machine zero
Data unit
Setting unit IS-B IS-C
Metric input 0.001 mm 0.0001 mm
Inch input 0.0001 inch 0.00001 inch
Data range
IS-B IS-C
Metric input -9999999999 -999999
999999
Inch input -9999999999 -999999
999999
1 1 9 KEY_P_NUM
Data meaning Number of active keys at a time
Data unit piece
Data range 25
1 2 0 REF1_COORDn
c1 2 1 REF1_COORDn
1 2 2 REF2_COORDn
1 2 3 REF2_COORDn
Data type Word axis
Data meaning REF1_COORDn 1st reference point machine coordinates
REF2_COORDn 2nd reference point machine coordinates
REF3_COORDn 3rd reference point machine coordinates
REF4_COORDn 4th reference point machine coordinates
Data unit
Setting unit IS-B IS-C
Chapter 3 Parameters
389
Volume Connection
Metric input 0.001 mm 0.0001 mm
Inch input 0.0001 inch 0.00001 inch
Data range -9999999999999999
1 4 0 TWEAR_MAX
Data meaning + or limit of each input wear in TOOL OFFSET&WEAR interface
Data unit
Setting unit IS-B IS-C
Metric input 0.001 mm 0.0001 mm
Inch input 0.0001 inch 0.00001 inch