Setting unit Data unit
Metric machine mm/min
Inch machine 0.1inch/min
[Data range] 10~99999999
1 1 4 REF_OFFSETn
[Data type] Word axis
[Data meaning] Offset of each axis machine zero
[Data unit]
Setting unit IS-B IS-C
Metric input 0.001 mm 0.0001 mm
Inch input 0.0001 inch 0.00001 inch
[Data range]
IS-B IS-C
Metric input -99999~99999 -999999~
999999
Inch input -99999~99999 -999999~
999999
1 1 9 KEY_P_NUM
[Data meaning] Number of active keys at a time
[Data unit] piece
[Data range] 2~5
1 2 0 REF1_COORDn
c1 2 1 REF1_COORDn
1 2 2 REF2_COORDn
1 2 3 REF2_COORDn
[Data type] Word axis
[Data meaning] REF1_COORDn 1st reference point machine coordinates;
REF2_COORDn 2nd reference point machine coordinates;
REF3_COORDn 3rd reference point machine coordinates;
REF4_COORDn 4th reference point machine coordinates
[Data unit]
Setting unit IS-B IS-C
Chapter 3 Parameters
389
Volume Ⅲ Connection
Metric input 0.001 mm 0.0001 mm
Inch input 0.0001 inch 0.00001 inch
[Data range] -99999999~99999999
1 4 0 TWEAR_MAX
[Data meaning] + or – limit of each input wear in TOOL OFFSET&WEAR interface
[Data unit]
Setting unit IS-B IS-C
Metric input 0.001 mm 0.0001 mm
Inch input 0.0001 inch 0.00001 inch