TOMATECH AUTOMATION
No. Content Remark
000 Emergent stop alarm and ESP open circuit
001 Called programs do not exist or cannot be opened
002 G command values are negative or with decimals
003 Characters are less than 2 or more than 11 for one word
004 Address error (address is A~Z)
005 Illegal command value
006 Block numbers are negative or with decimals
007 Illegal G commands
008 Execute G96 when the spindle analog voltage control is invalid
009
Command movement distance when G commands in group 00 and 01
are not input and there are invalid commands in group 01
010 There are the same addresses in one block
011 There are more than 40 words in one block
012
Command values exceed their valid range or command addresses which
cannot be omitted is omitted
013
Input S commands except for S00~S99 when the spindle analog voltage
control is invalid
014 G commands in group 00, 01 and 12 cannot be in the same one block
015
Execute M commands for spindle automatic gear shifting when the
spindle analog voltage control is invalid
016 Tool offset numbers exceed their valid range(0~32)
017 Tool number exceeds the range of No.084 parameter
018
The data specified by the interpolation command cannot form a correct
curve, or there is no necessary command, or the data exceeds No.154
range
019
The tool group number exceeds the range ( 1~32 ) in the tool life
management
020 Cannot execute T command in C tool nose radius compensation, cancel it
024 There is no G11 or G13.1 in the program
025 There is no tool in the current tool group in the tool life management
026 The current tool group has not been defined in the tool life management
027
The tool quantity exceeds 8 in the current tool group in tool life
management
028 The tool life management function is invalid and G10 L3 cannot be used
029 G11 cannot be in front of G10
030 X movement distance isn’t zero in G33