TOMATECH AUTOMATION
4. Tool life function use
Command format:
Txx99: end of current used tool group, start the tool and execute the life management in
XX
group.
Txx88: cancel the tool offset in XX group
Two examples are as follows:
Application example:
O0000 (O0000)
…
T0199; End of previous tool group, and start the tool in 01 group
…
T0188; Cancel tool offset in 01 group(current used tool offset)
…
T0508; Use No.05 tool and 08 tool offset without life management
…
T0500; Cancel No.05 tool offset
…mming
T0299; End of No.05 tool and start the tools in 02 group
…
T0199;
End of tools in No.02 group, start tools in No.02 group, and
start the next tool when there are many tools in No.01 group.
…
5. Tool life count:
When the count result is for the used life value being more than or equal to the setting
value of the life data, the next tool group number selects the standby tool in the
commanded selection tool group and the new selected tool will be counted, the count will
be continuously executed and the system alarms to output to PLC when all tool life in the
tool groups reaches and there is no standby tools. Executing the counting in MDI mode is