TOMATECH AUTOMATION
6. G, F signals relevant to tool life function
a Tool change signal TLCHF0640
Type output signal
Function inform PLC that the last tool life ends of in this group
Output condition the signal is set to 1, the last tool life in one group ends, all other tool
life ends.
b New tool selection signal TLNWF0641
Type output signal
Function inform a new tool in some tool group has been selected
Output condition the signal is set to 1 and a new tool in some tool group has been
selected.
c Tool change reset signal TLRSTG0487
Type input signal
Function clear all execution data
Operation when the signal is set to 1, the control unit clears the used tool life data of in
all groups; the tool state is reset to the unused.
Note: when the automatic operation signal OP is “0”, the tool change reset signal TLRST is valid.
d Tool skip signal TLSKPG0485
Type input signal
Functionuse the following two methods to change the tools which have not reached
the
life:
1 When LIFJNO.2#4is set to 1the selection signals of the tool group number
G47#0~#4specify the tool group number, then, the tool skip signal TLSKP
becomes “1”the next T command skips the tool which is being used of the
current group, and the tool which life has not reach in the group specified by
G47#0~#4 is used.
2When LIFJNO.2#4is set to 0the group numbers specified by the tool group
number signal G47#0~#4are invalid, the tool skip signal TLSKP becomes “1”,
the machine skips to the next tool in the current used tool group.
Operationwhen the signal is set to 1, the operation described in [Function] is executed.
Note: When cycle start light signal(STL) and feed pause light signal(SPL) must be “0”, inputting
TLSKP signal
is valid.
e Tool group number selection signal TL01~TL16G47#0~#4
Type input signal
Function when TLSKP is input, using the tool group selection signal TL01~TL16
specifies the tool group number with the binary system. The specified tool
group number = G47#4~#01.
Operation specify the selected tool group
Programming

Table of Contents