Multi Pro 5800 Page 8 − 75 GeoLink Spray System
Disassembly (Fig. 79)
1. Remove the nozzle valve assembly from machine
(see Spray Control Manifold Assembly in this chapter).
2. Disassemble nozzle valve assembly as needed. Dis-
card any removed O−rings and gaskets.
NOTE: See Nozzle Valve Service in this chapter for dis-
assembly and assembly information. The valve actua-
tors are not serviceable. See Spray System Valve
Actuators in Chapter 6 − Electrical System in this manu-
al for actuator testing information.
Assembly (Fig. 79)
NOTE: Replace, do not reuse gaskets and O−rings.
Coat O−rings and gaskets with vegetable oil or silicone
grease before installation to reduce damage during as-
sembly.
1. Assemble nozzle valve assembly.
2. Install nozzle valve assembly on machine (see
Spray Control Manifold Assembly in this chapter).