Phone Provisioning
83
Values
Default
5
Web UI
Settings->Auto Provision->Wait Time(1~100s)
Parameter
static.zero_touch.network_fail_wait_times
<y0000000000xx>.cfg
Description
It configures the reconnection times when zero touch module fails to obtain network
parameters.
Permitted
Values
Integer from 1 to 2147483646
Default
8
Parameter
static.zero_touch.network_fail_delay_times
<y0000000000xx>.cfg
Description
It configures the duration time (in milliseconds) of every reconnection when zero
touch module fails to obtain network parameters.
Permitted
Values
Integer from 1000 to 2147483646
Default
1000
Parameter
static.features.hide_zero_touch_url.enable
<y0000000000xx>.cfg
Description
It enables or disables the phone to hide the provisioning URL item on the Zero Touch
screen.
Permitted
Values
0-Disabled
1-Enabled
Default
0
PnP Provision Configuration
The following table lists the parameters you can use to configure PnP provision.
Parameter
static.auto_provision.pnp_enable
<y0000000000xx>.cfg
Description
It triggers the Plug and Play (PnP) feature to on or off.
Permitted
Values
0-Off
1-On, the IP phone will broadcast PnP SUBSCRIBE messages to obtain a provisioning
server address during startup.
Default
1
Web UI
Settings->Auto Provision->PNP Active

Table of Contents

Other manuals for Yealink T40G

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Yealink T40G and is the answer not in the manual?

Yealink T40G Specifications

General IconGeneral
SIP Accounts3
Wall MountableYes
Opus CodecNo
Display2.3 inch 132x64-pixel graphical LCD
NetworkDual-port Gigabit Ethernet
PoEYes
Headset SupportYes, RJ9 port
Power AdapterOptional
Voice CodecsG.722, G.711(A/μ), G.729AB, G.726
Local Phonebook1000 entries

Related product manuals