EasyManuals Logo

Allied Telesis SwitchBlade x3100 Series User Manual

Allied Telesis SwitchBlade x3100 Series
940 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #38 background imageLoading...
Page #38 background image
Introduction How to Get Command Help
Software Reference for SwitchBlade x3100 Series Switches (Setting Up the Switch)
1-8
1. For command string help, type in the start of a command and enter a space and a “?” at the end of the line.
The SBx3112 will display a list of possible parameters. After entering a parameter and a “?”, online help pro-
vides an explanation of the parameter. Entering a “?” alone will display all of the verbs available.
2. For complete online help, type HELP and the command. If the command is incomplete, there is an error
message. Entering a space and a “?” will show the next valid parameter. When the command is complete, a
complete description of the command is displayed.
Following is an example of using HELP for a command.
>HELP SHOW SNMP
ATI 200G Central Fabric Controller Help version 14.2.0 - English Version
SYNTAX:
SHOW SNMP
DESCRIPTION:
The SHOW SNMP command displays information about the device's SNMP
agent.
The following is example output from the SHOW SNMP command:
SNMP configuration:
---------------------------------
Status .......................... Enabled
Authentication failure traps .... Enabled
Community ....................... public
Access ........................ read-only
Status ........................ Enabled
Traps ......................... Enabled
Open access ................... Yes
Community ....................... Administration
Access ........................ read-write
Status ........................ Disabled
Traps ......................... Disabled
Open access ................... No
SNMP counters:
-------------------------------
inPkts ........................ 0 outPkts ........................
inBadVersions ................. 0 outTooBigs .....................
inBadCommunityNames ........... 0 outNoSuchNames .................
inBadCommunityUses ............ 0 outBadValues ...................
inASNParseErrs ................ 0 outGenErrs .....................
inTooBigs ..................... 0 outGetRequests .................
inNoSuchNames ................. 0 outGetNexts ....................
inBadValues ................... 0 outSetRequests .................
inReadOnlys ................... 0 outGetResponses ................
inGenErrs ..................... 0 outTraps .......................
inTotalReqVars ................ 0
inTotalSetVars ................ 0
inGetRequests ................. 0
inGetNexts .................... 0
inSetRequests ................. 0
inGetResponses ................ 0
inTraps ....................... 0
Parameter Meaning
Status The status of the SNMP agent or the specified
community (ENABLED or DISABLED)
Authentication Whether or not the SNMP agent generates a trap
Failure Traps on an authentication failure for an incoming
SNMP packet (ENABLED or DISABLED)
Community The name of an SNMP community on the device.
Access The access rights for the SNMP community
(READ-ONLY or READ-WRITE)

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Allied Telesis SwitchBlade x3100 Series and is the answer not in the manual?

Allied Telesis SwitchBlade x3100 Series Specifications

General IconGeneral
BrandAllied Telesis
ModelSwitchBlade x3100 Series
CategorySwitch