Optical Device Data Access Debug Interface
Software Reference for SwitchBlade x3100 Series Switches (Alarms and Troubleshooting)
8-48
Display example for an XE4 interface on a XE4 card that does not have an XFP present:
officer SEC>> sh int 11.1 optics
sh int 11.1 optics
officer SEC>>
Display example for an interface on a XE4 card that has an XFP present.
E135 - manager SEC>> show interface 11.0 OPTICS
--- Interface Optics ---
Interface.......................... 11.0
Type............................... XE
State.............................. UP-UP
Description........................ <none>
Optics Specification
Transceiver Type................ XFP
Nominal Bit Rate................ 10000 Mbits/sec
Vendor Name..................... ATI
Vendor Part Number.............. AT-XPSR
Wavelength...................... 850 nm
Internal Temperature............ 26.6 C (79.9 F)
Transmit Power.................. 0.5660 mW
Receive Power................... 0.4105 mW
Vendor Hardware Revision........ Not Available
Vendor Firmware Revision........ Not Available
Vendor Software Revision........ Not Available
officer SEC>> show interface 0.18 optics
--- Interface Optics ---
Interface.......................... 0.18
Type............................... GE
State.............................. UP-UP
Description........................ <none>
Optics Specification
Transceiver Type................ SFP
Nominal Bit Rate................ 1300 Mbits/sec
Vendor Name..................... ATI
Vendor Part Number.............. AT-SPSX
Wavelength...................... 850 nm
Internal Temperature............ 42.7 C (108.9 F)
Transmit Power.................. 0.2046 mW
Receive Power................... 0.2153 mW
Vendor Hardware Revision........ Not Available
Vendor Firmware Revision........ Not Available
Vendor Software Revision........ Not Available
8.10.4 Debug Interface
From the debug level, a targetshell level command displays the raw memory data from the SFP/XFP memory.
For interfaces on GE24 or XE4 cards, the user enters the debug level, enables targetshell on the CFC, and then
runs the command. The user could also use a tsh level OAM command to do the same thing.
Note: Contact Allied Telesis Support for more on using the debug mode.