Page #622 background imageLoading...
Page #622 background image
Introduction Configuring the Egress Port Rate Limiting
Software Reference for SwitchBlade x3100 Series Switches (Access and Security)
6-62
ADD EGRESSLIMITER INTERFACE
Syntax
ADD EGRESSLIMITER=limitername INTERFACE={ type:id-range | id-range
| ifname-list | ALL }
Description Associates an EGRESSLIMITER with one or more INTERFACEs. This limits the traffic
that the system transmits through this INTERFACE to the values specified by the
EGRESSLIMITER. A particular INTERFACE may only be associated with one EGRESSLIM-
ITER, but a particular EGRESSLIMITER may be associated with any number of ports.
Options The following table gives the range of values for each option that can be specified with
this command and a default value (if applicable).
Example
ADD EGRESSLIMITER=sub_gold INTERFACE=ETH:7.0
Option Description Default Value
EGRESSLIM-
ITER
The name of the EGRESSLIMITER that is being added to
the INTERFACE(s).
INTERFACE The interface the EGRESSLIMITER will be associated
with.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Allied Telesis SwitchBlade x3100 Series and is the answer not in the manual?

Allied Telesis SwitchBlade x3100 Series Specifications

General IconGeneral
BrandAllied Telesis
ModelSwitchBlade x3100 Series
CategorySwitch
LanguageEnglish

Related product manuals