Event Logging TRACE Commands User Event Logging
8-41
Software Reference for SwitchBlade x3100 Series Switches (Alarms and Troubleshooting)
FORMAT Allows users to specify the format of the Trace logs as
they are displayed. Valid formats are:
FULL - Displays the entire contents of the Trace log
including log type, date and time, the slot where the log
was generated, sequence number and the full message
body.
SUMMARY - Displays a one-line summary of the man-
agement log. The summary includes the log type, time,
and the first line of the message body.
REVERSE Reverses the normal display order of management logs
(displaying the management logs in oldest to newest
order).
SEQUENCE Allows for the display of management logs that match
the specified range of sequence numbers.
Sequence number ranges can be either a single sequence
number, an explicit range of sequence numbers (e.g.,
100-200) or an operation-specified range of sequence
numbers (e.g., <200)
The following are the valid operations:
< - less-than - displays all logs with a sequence number
less than or equal to the given sequence number.
> - greater-than - displays all logs with a sequence num-
ber greater than or equal to the given sequence number.
TAIL Allows for the display of a certain number of the newest
logs. If a numeric argument is not supplied, the newest
20 logs are displayed, otherwise the optional numeric
argument is taken as the number of logs to display, if
that number of logs exists.
TIME Filters logs based on the time at which the log occurred.
The time may be specified as an exact value (hh:mm:ss),
an explicit range (hh:mm:ss-hh:mm:ss) or as an opera-
tion-specified range of values.
The following operations are valid:
< - less-than - displays all logs with a time less than or
equal to the specified value.
> - greater-than - displays all logs with a time greater
than or equal to the specified value.
Option Description Default Value

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Allied Telesis SwitchBlade x3100 Series and is the answer not in the manual?

Allied Telesis SwitchBlade x3100 Series Specifications

General IconGeneral
BrandAllied Telesis
ModelSwitchBlade x3100 Series
CategorySwitch
LanguageEnglish

Related product manuals