The following information is displayed:
Input
Logical port representing the connection to the ECMG assigned automatically. This
number is used internally as well as for generating alarms.
Channel
The SimulCrypt Channel ID used for the CA system
Name
For reference in the GUI only
IP
IP address of the ECMG
Port
TCP port of the ECMG
CAS ID
CA vendor specific ID
Sub ID
CA vendor specific sub ID
State
Status of ECMG connection, either OPEN or NOT CONNECTED.
To change an, ECMG channel connection click on the existing ECMG entry and enter the new configuration.
It is possible to have several ECMG connections simultaneously but the CAS ID has to be
uniquely defined. If the same CAS ID is used, a real SimulCrypt will not work as the CA
Descriptor in the PMT will be identical for both ECMs. In this case, private data must be
used by STBs to distinguish ECMs.