APPEAR AS Confidential 182/352
The following parameters are available for configuration:
Name
By default, these four values are extracted from the incoming streams automatically.
They can be overwritten manually by deselecting Keep Original and entering a new
value.
If a manual Service Type is selected, this value must be specified.
Service Id
PMT PID
Provider
Service type
Priority
An internal system parameter which may be used for different purposes. Currently it is
an attribute used by the Output Redundancy system only.
Monitor Port
Provides a way to monitor a service if the system is configured with a decoder
module. If enabled, a copy of the service is sent to the selected decoder. If the service
is descrambled, the service is copied after descrambling.
Refer to the Input Redundancy (Section) for more information on the Backup source and Switching mode
parameters.
Descrambler
Select which descrambler to be used for removing the incoming encryption. If
multiple services are being descrambled, they must originate from the same input
port (same MPTS).
Alt. CAM mode
Configuration of these values is moved to the main conditional access page in the
Navigation Pane.