Protected by copyright. Copying for private or commercial purposes, in part or in whole, is not
permitted unless authorised by AUDI AG. AUDI AG does not guarantee or accept any liability
with respect to the correctness of information in this document. Copyright by AUDI AG.
♦ Used oil collection and extraction unit - V.A.G 1782-
Procedure
– Use oil collection and extraction unit - V.A.G 1782- to draw off
hydraulic fluid for power steering from reservoir.
Note
Place cloth under power steering reservoir to catch escaping hy‐
draulic fluid.
– Remove power steering reservoir.
Installation is carried out in the reverse order; note the following:
– Top up power steering fluid and bleed steering system ⇒ Rep.
gr. 48 .
Tightening torque
Component Nm
Power steering reservoir to bracket 9
5.5.2 Removing air cleaner (top section) - ve‐
hicles with 6-cyl. and 8-cyl. engine
Procedure
– Detach air hose -2- at air cleaner housing.
– Unplug electrical connector -3-.
– Remove bolts -arrows- and detach air cleaner (top section).
– Detach connecting hose -1-.
Installation is carried out in the reverse order; note the following:
Note
Secure all hose connections with the correct type of hose clips
(same as original equipment) ⇒ Electronic parts catalogue .
Audi A8 2003 ➤
Electrical system - Edition 08.2014
5. Gas discharge headlights - USA vehicles 183