Design and Function
3
CCD CAM 100 – Installation and Operating Manual 27/198
3.6 Measuring Range
The measuring range is the range in which the CCD camera
detects contrast transitions.
LED
projection point
Illumination
Material
Measuring range (variable)
Fig.9: Marking of the measuring range
When changing the focal length on the zoom lens, you adapt the
measuring range to the maximum width of your material. In doing
so, all contrast transitions (material edges) that should be detected
by the CCD camera must be located within the measuring range.
During setup mode, three green LED projection points mark the
measuring range and thus make the setup and the precise align-
ment of the camera easier.
The actual measuring range of the CCD camera is approx.
5% greater than the range that is marked by both outer
LED projection points.