4
Technical Specifications
34/198 CCD CAM 100 – Installation and Operating Manual
4 Technical Specifications
DANGER
Danger of death when operated in potentially explosive areas!
►
The system must not be installed or operated in potentially
explosive areas.
Ambient Conditions
Working temperature +10…+50°C (+50…122°F)
Storage temperature -10…+70°C (+14…+158°F)
Humidity during operation 5…90%, non-condensing
Place of installation Closed, dry building,
height above sea level < 2,000m
Exceptions to these conditions are only possible after consultation
with BST.
Power Supply
Voltage 24V⎓ ±10% (including ripple)
Current 250mA (without external load)
Power consumption 6W (without external load)
Reverse polarity protection yes
Connection Supply via CAN bus interface
(X100) or Power over Ethernet
PoE (X30)
Protection Category
Protection category IP54
Measuring Range
Measuring range variable (see diagram,
Determining the Measuring
Distance, page 52)
Marking in setup mode using LED projection points
Measuring distance min. 250mm
max. 1,600mm
Number of edges that can be
read
max. 8 (CAN bus)
max. 256 (Ethernet)