Chapter 10
| Interface Commands
Transceiver Threshold Configuration
– 379 –
transceiver-monitor This command sends a trap when any of the transceiver’s operational values fall
outside of specified thresholds. Use the no form to disable trap messages.
Syntax
transceiver-monitor
Default Setting
Disabled
Command Mode
Interface Configuration (Ethernet)
Example
Console(config)interface ethernet 1/1
Console(config-if)#transceiver-monitor
Console#
transceiver-threshold
current
This command sets thresholds for transceiver current which can be used to trigger
an alarm or warning message.
Syntax
transceiver-threshold current {high-alarm | high-warning | low-alarm |
low-warning} threshold-value
high-alarm – Sets the high current threshold for an alarm message.
high-warning – Sets the high current threshold for a warning message.
low-alarm – Sets the low current threshold for an alarm message.
low-warning – Sets the low current threshold for a warning message.
threshold-value – The threshold of the transceiver current.
(Range: 100-25500 in units of 0.01 mA)
Default Setting
High Alarm: 100 mA
HIgh Warning: 90 mA
Low Warning: 7 mA
Low Alarm: 6 mA
Command Mode
Interface Configuration (Ethernet)
Command Usage
If trap messages are enabled with the transceiver-monitor command, and a
high-threshold alarm or warning message is sent if the current value is greater
than or equal to the threshold, and the last sample value was less than the
threshold. After a rising event has been generated, another such event will not