Chapter 18
| VLAN Commands
Configuring VLAN Interfaces
– 478 –
Example
The following example shows how to prevent port 1 from being added to VLAN 3:
Console(config)#interface ethernet 1/1
Console(config-if)#switchport forbidden vlan add 3
Console(config-if)#
switchport
ingress-filtering
This command enables ingress filtering for an interface. Use the no form to restore
the default.
Syntax
[no] switchport ingress-filtering
Default Setting
Disabled
Command Mode
Interface Configuration (Ethernet, Port Channel)
Command Usage
â—† Ingress filtering only affects tagged frames.
â—† If ingress filtering is disabled and a port receives frames tagged for VLANs for
which it is not a member, these frames will be flooded to all other ports (except
for those VLANs explicitly forbidden on this port).
â—† If ingress filtering is enabled and a port receives frames tagged for VLANs for
which it is not a member, these frames will be discarded.
â—† Ingress filtering does not affect VLAN independent BPDU frames, such as GVRP
or STA. However, they do affect VLAN dependent BPDU frames, such as GMRP.
Example
The following example shows how to set the interface to port 1 and then enable
ingress filtering:
Console(config)#interface ethernet 1/1
Console(config-if)#switchport ingress-filtering
Console(config-if)#