iPECS-LIK
Feature Description & Operation Manual
2.53
LBC (LOUD BELL CONTROL)
Description
The iPECS hardware is equipped with relays that activate External Control Contacts. Each
contact is assigned to one of several functions including a Loud Bell Control. If used as a Loud
Bell Control, the contact will activate when:
External Page is accessed
Assigned Station receives ring (LBC)
UNA (Universal Night Answer) CO/IP line receives a call while in the Night or Timed
Ring mode.
Operation
System
Operation of the relays is automatic when defined
Conditions
1. The number of available contacts is given in Table 1.2-1.
2. When assigned to activate as a Loud Bell Control, CO/IP ring, transfers, and tone
ring Intercom calls to the assigned station will activate the contacts.
3. The contacts are rated at 1 amp, 24 VDC.
4. If the system is in the Night or Timed ring mode with External Night Ring enabled, a
call on a CO/IP line assigned with UNA will activate the LBC 1 contact. This
permits operation of an external night ring device. While in the Night or Timed ring
mode, LBC1 is not activated by ringing at the assigned station.
Programming
Universal Night Answer (PGM 141-Btn 7)
External Night Ring (PGM 160-Btn 6)
External Contact Control (PGM 168)
Related Features
Universal Night Answer
Door Open
Hardware
External Control Contact connected to an external loud bell.