iPECS-LIK
Feature Description & Operation Manual
Operation
Case of LD : The method of disconnecting in outgoing and incoming
Programming
1. Program 149-B 2 (Snd Sub Ans/IC & Wait Sub Ans/OG (4))
2. Program 142-B 3 (SMDR Metering Unit (4 : SPR)
Conditions
1. It’s not working hot line function that it can be connected without pressing any
digits in case of LD.
2. It can be disconnected automatically by the time of PGM 149-B12, co ring stop
timer in case of RD when there is no answer from receiver.
PROGRAMMING
CO
1. PGM 149-B 1( LCO(1) / RD(2) / LD(3) )
2. PGM 149-B 12( CO Ring Stop Timer)
Related Features
Hardware
4.19
MULTIPLE CLI
Description
This feature provides flexibility for CLI service.
In PGM 114, CLI Station Number(PGM 114 – F6) can be programmed.
Station CLI 2 ~ Station CLI 5 will be newly made.
By using these new CLIs, a specific CLI can be provided to the called party.
The name – [CLI Station Number] will be changed to [Station CLI 1].
In PGM 143 – Station CLI Type, CLI can be chosen between Station CLI 1 to Station CLI 5.
It will be newly made.
Station CLI 1 means Original CLI Station Number(PGM 114 – F6) is used.
Station CLI 2 ~ Station CLI 5 means newly added CLI Station Numbers are used.
In PGM 143 – CLIP table index, CLIP can be chosen.
The range is available from 00 – 50.
In case of CLIP table index 00 to 49, then normal CLI making way is applied.
In case of CLIP table index 50, then ONLY Station CLI Station Number(PGM 114 – F6) can be
sent by CLI without adding any prefix.