iPECS-LIK
Feature Description & Operation Manual
Issue 6.1
302
4.18
Multi-function Analog Trunk Module (MATM) Service
Description
MATM(Multi-function Analog Trunk Module) can support 5 kinds of CO type. It has 4 kinds of
module in a board for plug-in/off. It can be programmed 5 kinds of CO Type respectively by
programming. EMIU has EMC and EMD, EMC is the continuous signal and EMD is
discontinuous.
COIU (Central Office Interface Unit)
EMIU (E&M Interface Unit)
LDIU (Loop Dial Interface Unit)
RDIU (Ring Down Interface Unit)
RU (Ring Unit) : Ring generator option module for RDIU
CO Trunk Function
Polarity-reverse detection
Ring detection
Loop seizure
Loop dialing
E&M Trunk Function
E/M line surge protection and over-current protection
E&M Type V (E-line: current detection, M-line: Open or GND) 지원
LD Trunk Function
Polarity-reverse detection
Polarity-reverse send
Loop seizure
Loop dialing
RD Trunk Function
Ring detection
Ring send
4.18.1 E&M Trunk Function
Description
There are two kinds of function for 2w or 4w way for E&M. It should have different signal line,
so consist of different h/w interface respectively.
Operation
2W method
Setting of external analogue
port
1. Connect as the same port in both case for voice and signal port.(1:1).
2. Signal port must be crossed line.
3. Be used all ports chosen.
LOOP Example for self testing)
Signal/Voice port 1 <-> Signal/Voice port 3