iPECS-LIK
Feature Description & Operation Manual
Issue 6.1
164
NUM II Flex Field II for incoming call, displays Ring duration, CLI or CPN or
blank, (PGM 177-Btn 23)
Disconnect Cause, optional output (PGM 177-Btn 29), with value:
DC
01~7F: Follow cause value of Q.931 specification,
81: Disconnected, toll restricted
84/85: Disconnected, disconnect supervision
0: Other
The SMDR record output for internal calls is as shown in the figure below.
---- Site Name :
-----------------------------------------------------------------------------------------
STA
CO
TIME
START
DIALED
NUMBE
R
-------------
- E103
S103
E Conf Rm
1 P123
COST
ACCOUN
T
CODE
--------------
CPN
NUMBER
--------------
-------
-------
-------
---------------------
--------------
102
00:00:01
06/11/08 10:53
102
00:00:00
06/11/08 14:13
102
00:00:10
06/11/08 11:05
120
00:00:03
06/11/08 11:11
STA
DIALED
Meaning
100
E101
1) Station 100 called station 101 and station 101 answered.
2) In a conference, station 100 was a conference master, station 101 was a
conference member.
105
S103
Station 105 sent an internal SMS to station 103.
110
E Conf Rm 1
Station 110 was the member of conference room 1.
120
P123
Station 120 paged station 123.
Operation
System
For real-time SMDR, records are output after completion of the call as shown in the figure
above
System Attendant
To print SMDR records
1. Press the [PGM] button.
2. Dial 0111, the SMDR print code.
3. Enter the desired station range.
4. Press the [SAVE] button.
To delete stored records
1. Press the [PGM] button.
2. Dial 0112, the SMDR delete code.
3. Enter the desired station range.
4. Press the [SAVE] button.

Table of Contents