310
2. The call will be placed on the same path as originally used. If the path is busy, an
available CO/IP line in the same group will be seized.
3. The ACNR Retry Counter decrements by one when the system completes the
dialed number.
4. When the ACNR Pause Timer expires, if the station is in a busy state, the ACNR
Delay Timer is invoked.
5. Upon completion of dialing, the system will monitor the call for progress signals.
6. To preserve ACNR feature in activated state, SLT user does not go On-Hook.
7. While ACNR dialing or waiting state, if SLT user goes On-Hook, then SLT ACNR is
deactivated, automatically.
8. During ACNR dialing SLT, cannot receive any new call.
Programming
SYSTEM
1. ACNR Delay Timer (PGM 180-Btn 8)
2. ACNR Pause Timer (PGM 180-Btn 9)
3. ACNR Retry Counter (PGM 180-Btn 10)
4. ACNR Tone Detect Timer (PGM 180-Btn 11)
NUMBERING PLAN 1 SLT ACNR Code (PGM 109-Btn 18 58#)