Updating the golden image using the iRMC S6 web interface
Log in to the iRMC S6 web interface.
Select the T
ools menu.
Open the Update page.
In the BIOS Update group, set the Update Source to Image file.
Set the Image to Flash to Both or Recovery.
Click Start Update to Perform.
For more information on iRMC settings, see the iRMC user guides.
Updating the golden image using the Redfish API of the iRMC S6
Further information about the Redfish API of the iRMC S6, see the iRMC S6
Redfish documentation on the Fujitsu support internet pages at:
https://ts.fujitsu.com/support/
5.3.20
Setting boot priority
If the boot priority has been changed after installing or replacing a bootable
device, set it to the same priority as before the installation or replacement. To
check the boot priority, see "Checking boot priority" on page 93.
Enter the BIOS.
Select the Boot menu.
Navigate to the Boot Maintenance Manager menu and press the [Enter]
key to display the options.
Navigate to the Boot Options menu and press the [Enter] key to display the
options.
Basic software procedures
120 Upgrade and Maintenance Manual RX2540 M7