Power class Power PSU
4 1600 W AC PSU Platinum
1600 W AC PSU Titanium
1600 W HVDC PSU 380 V
5 2200 W AC PSU Platinum
6 2400 W AC PSU Titanium
All different PSUs can be installed, removed or replaced in the same
way.
Assembly rules
Mixed assembly of PSUs from dif
ferent power classes (e.g. power class 1 or
power class 2) within a system is not supported.
Mixing of Platinum and Titanium PSUs within same class (e.g. power class
2) within a system is not supported.
Mixing of Platinum PSUs within same power class and different
manufacturer (e.g. power class 1) within a system is supported.
Always install a dummy cover into an unused PSU bay to comply with
applicable EMC regulations and satisfy cooling requirements.
For a redundant power supply configuration you need always two PSUs with
the same power class.
Power supply unit (PSU)
RX2540 M7 Upgrade and Maintenance Manual 125