Some SSDs / PCIe SSDs have a write life (limited life component). Ask
the customer to check the write status before replacing the spare part. If
the product has reached the end of its life, ask the customer to purchase
it again.
For Japan, refer to the following:
https://jp.fujitsu.com/platform/server/primergy/support/parts/#parts2
Preliminary steps
▶
If applicable, "Removing the front cover with lock" on page
49.
▶
"Locating the defective server" on page 47.
▶
"Locating the defective component" on page 48.
Removing the defective 2.5-inch HDD/SSD module
▶
Remove the HDD/SSD module, see "Removing a 2.5-inch HDD/SSD
module" on page 181.
▶
If the new HDD/SSD module does not have an installation frame, replace
the installation frame, "Handling HDDs or SSDs without installation frame"
on page 138.
Installing the new 2.5-inch HDD module
▶
Install the HDD/SSD module, see "Installing a 2.5-inch HDD/SSD module"
on page 179.
Concluding steps
▶
If applicable, "Installing the front cover with lock" on page 71.
▶
If the HDD/SSD is configured using a RAID controller with a RAID level
higher than "0", the rebuild will start automatically, see "Performing a RAID
array rebuild" on page 108.
▶
For a spare disk, verify that it is set to Hotspare in iRMC S6 web interface.
Hard disk drive (HDD) / solid state disk (SSD)
184 Upgrade and Maintenance Manual RX2540 M7