If the PCIe SSD module is controlled by a RAID controller of the PRAID
EP5xxi/CP5xxi/EP6xxi family, the PCIe SSD module can be installed
during operation (hot-plug), see "Removing a 2.5-inch HDD/SSD
module" on page 181.
CAUTION
All HDD/SSD modules (drives) must be uniquely identified so that they
can be reinstalled in their original bays later
. If this is not done, existing
data can be lost.
Some SSDs / PCIe SSDs have a write life (limited life component). Ask
the customer to check the write status before replacing the spare part. If
the product has reached the end of its life, ask the customer to purchase
it again.
For Japan, refer to the following:
https://jp.fujitsu.com/platform/server/primergy/support/parts/#parts2
Preliminary steps
If applicable, "Removing the front cover with lock" on page
49.
"Locating the defective server" on page 47.
Identify the physical location of the PCIe SSD module, see "2.5-inch HDD/
SSD configurations" on page 165.
Prepare the removing of the PCIe SSD module.
Depending on your configuration and OS: "Shutting down the server" on
page 50.
Removing the defective 2.5-inch PCIe SSD module
Remove the PCIe SSD module, see "Removing 2.5-inch PCIe SSD
modules" on page 188.
If the new PCIe SSD module does not have an installation frame, replace
the installation frame, "Handling HDDs or SSDs without installation frame"
on page 138.
Hard disk drive (HDD) / solid state disk (SSD)
RX2540 M7 Upgrade and Maintenance Manual 191