Fasten the four captive screws in the sequence printed on the LC heat sink
(1 to 4), by proceeding as follows:
T
ool: Torx 30 screwdriver
Torque: 0.9 Nm
First, fasten the captive screws 1 and 2 completely.
Fasten the captive screws 3 and 4 completely.
Proceed for the second LC heat sink in the same way.
Note when tightening the screws of the LC heat sink:
As shown in the figure below, tighten the screws while checking the screw
tip until it is visible through the screw hole.
When you reach the above position, hold the screwdriver with two fingers
and tighten the screw firmly
.
Proceed for the second LC heat sink in the same way.
Liquid cooling (LC)