Tools: Replacing the system board:
Phillips PH2 / (+) No. 2 screw driver
Torx 30 screw driver
Magnifying glass for inspecting CPU socket springs
(recommended)
Replacing the TPM:
Bit screw driver
flat nose pliers
TPM bit insert
(*)
thin slotted screw driver (2 x 0.4 mm)
(*)
(*)
For Japan:
Dedicated TPM screw driver (CWZ8291A)
TPM module fixing tool (S26361-F3552-L909)
Note on BIOS or iRMC S6 firmware restore feature
BIOS or iRMC S6 firmware restore feature is executed at the same time
as the power cord is connected after the system board replacement.
Depending on the configuration of your server the firmware restore
requires dif
ferent time, see "States of power-on indicator and time
duration during firmware restore" on page 541:
18 - 38 minutes (systems with PFR feature).
Do not perform the following operations after connecting the power cord.
Please wait for the above time to elapse.
Remove and reinsert the power cord
Power button on/off
Connecting and disconnecting other cables, etc.
For more information, see "Concluding steps" on page
519.
System board and components
RX2540 M7 Upgrade and Maintenance Manual 511