Status Description
flashing orange Non-CSS component failure detected.
Possible causes:
–
System is out of the specified temperature range
– Defective sensor
– CPU error
– Error detected by server management software
CSS indicator (3)
Status Description
off No critical event detected (CSS component).
orange on Prefailure event detected (CSS component).
flashing orange CSS component failure detected.
Note on CSS and Global Error indicators on the COP:
If CSS and Global Error indicators are located in the same place on the
COP of the server, also check the indicators on the front panel to
determine if a CSS or Global Error event has been detected.
For more information on detected errors, see the System Event Log or
use the iRMC web interface.
iRMC-related status signals
ID indicator Global error
indicator
Description
flashing blue off A remote connection has been
established. Local VGA output has been
disabled during the remote session.
flashing blue flashing orange An emergency flash of the iRMC firmware
is in progress.
Appendix A
550 Upgrade and Maintenance Manual RX2540 M7