3. Operation of CON Related Controllers
119
2) Way to Handle Smart Tuning Function
Set the velocity and carrier load number to the set position number.
Select “Automatically Tune Acceleration from Transported Load and Velocity” from the ways
for tuning.
Select the position to have Smart Tuning Function and
touch it.
Select one from 0 (Transported Load No. 0) to 3
(Transported Load No. 3) and set to the transported load.
Set the necessary items except for acceleration and
deceleration such as target position.
Touch [Smart tuning].
Touch [Auto-tuning of acceleration from load and velocity].
Acceleration and deceleration after automatic tuning are
shown.
Touch [Yes].
3) Maximum acceleration speed and maximum deceleration speed are set for the indicated
velocity and transported load number.