6. Operation of ELECYLINDER
374
6.18 Easy Programming
The easy programming enables to have a stop time during operation or conduct a continuous
operation indicating the number of repeating times in the same test mode as the position
movement.
[How to Establish Setting]
Set the position number (0: backward end, 1: forward end) of the destination to the easy
programming input part (step). In order to have a pause between operations, use prepared five
timers T1 to T5. Timer can be set in 0.1 second unit from 0 to 99.9sec. When it is required to
repeat operation, input R (repeat indication symbol) at the end.
The number of steps available to indicate is 10 at maximum including R.
If there is a space, the step after that is not valid. The easy programming stops. Steps after R are
also invalid.
Touch [Easy programming] in Menu 2 screen.
Easy programming screen opens.
Touch [Example] and examples for how to construct a
program are displayed.
Touch [←] button to return to the previous screen.
Take this as a reference when constructing an Easy
programming.