3. Operation of CON Related Controllers
64
3.9.2.4 Operating Method of Updating Maintenance Information Related to Lubrication
Shown below is how to record the time of lubrication and how to reset the drive distance after
lubrication when lubrication to an actuator.
Last time lubrication, travel distance after lubrication and [Lubrication] button should be shown when
both the controller and actuators are applicable for the information management system and
Parameter No. 192 Actuator Identification System Use Flag is set to 1: Valid.
Touch [Lubrication] to display the password entry screen.
Enter '5119', and then touch [ENT].
Lubrication information clear confirmation window should be
displayed.
Touch [Yes].
Confirmation window for controller reboot should appear.
Touch [Yes].
If touch [No], controller would not reboot.
The lubrication time to the current day and time should be
updated and the value in the drive distance after lubrication
should be reset.